48V Victron off-grid pre-wired (120V)
December 8, 2025
SIGENERGY Sigenstor BAT
October 21, 2026SIGENERGY Sigenstor EC SP
$2,499.00
Split-phase hybrid inverter + EMS
one SKU, 6 field-set ratings
2:1 DC/AC ratio, 50 to 550 V
SigenStor BAT 6.0 / 9.0 US · 300 to 600 V
peak 17.1 kW for 10 s
with Sigen LoadHub
97.61 % CEC · THD < 2 %
UL 1741 SB · UL 3141
smart air cooling · 77 lb
Wi-Fi · Ethernet · RS485 · 4G option
SIGENERGY energy controller SigenStor EC SP US: the 11.5 kW split-phase hybrid with 23 kW of PV input
Hybrid inverter + EMS · 120 / 240 V split phase · one SKU, field-configurable from 3.8 to 11.5 kW · 4 MPPT · 2:1 DC/AC ratio · NEMA 4X · 10-year warranty
The SigenStor EC SP US ships as a single part number (11040057) and is set in the field to 3.8, 4.8, 5.7, 7.6, 9.6 or 11.5 kW. You buy one controller and match it to your service, your permit and your PV array.
The SIGENERGY energy controller at a glance
| Product | Sigen Energy Controller Split Phase US · SigenStor EC SP US · part no. 11040057 |
| Role | hybrid inverter and energy management system of the SigenStor 5-in-1 stack |
| AC output | 120 / 240 V split phase · 208 / 120 V supported · 60 Hz |
| Nominal power | 3.8 / 4.8 / 5.7 / 7.6 / 9.6 / 11.5 kW · field-configurable |
| PV input | up to 23 kW · 4 MPPT · 16 A each · 50 to 550 V MPPT window · 600 V max. |
| Backup output | 11.5 kW at 240 V · 5.75 kW at 120 V · 17.1 kW peak for 10 s |
| Backup switchover | 0 ms load-side disruption with Sigen LoadHub and Sigen Battery US |
| Battery | SigenStor BAT 6.0 / 9.0 US · 300 to 600 V · up to 6 modules per controller |
| Efficiency | 97.8 % max. · 97.61 % CEC |
| Enclosure | NEMA 4X · smart air cooling · -22 to 140 °F |
| Dimensions and weight | 27.6 × 11.8 × 10.2 in (700 × 300 × 260 mm) · 77.1 lb (35 kg) |
| Certifications | UL 1741 · UL 1741 SB · UL 1741 CRD · IEEE 1547-2018 · UL 1699B · UL 3141 · FCC Part 15 Class B |
The SIGENERGY energy controller, sold as the SigenStor EC SP US, is the brain of the SigenStor home energy system. First, it is a split-phase hybrid inverter with four MPPT inputs and up to 23 kW of PV. Then, it embeds the energy management system that decides where power goes: loads, battery, grid or EV. Moreover, it stacks directly on SigenStor BAT 6.0 and 9.0 US battery modules, up to six per controller. Finally, it ships as a single SKU that the installer configures from 3.8 to 11.5 kW. In short, it replaces the inverter, the EMS and the battery gateway with one outdoor-rated unit.
“The number that sold me on the EC SP is the 2:1 DC/AC ratio. On an 11.5 kW controller you can hang 23 kW of panels, which means the battery fills in winter when a conventional hybrid is still starved. Add the 0 ms switch with the LoadHub and the fact that one SKU covers every service size, and the stocking problem disappears for the installer.”
— Julien, Perma Batteries
One SKU, six power ratings: configuring the SigenStor EC SP
Sigenergy ships a single hardware unit and unlocks the output power in software. First, the installer selects 3.8, 4.8, 5.7, 7.6, 9.6 or 11.5 kW during commissioning. Then, the controller limits its on-grid and backup output accordingly. As a result, the same box fits a 100 A townhouse service and a 200 A service with a 23 kW array. Moreover, the AC switch rating scales with the setting, from 20 A to 60 A, so the breaker size follows the configuration. However, the PV input limit also scales: 2:1 of the configured AC rating, from 7.68 kW to 23 kW.
| Configured rating | Nominal AC power | Max. AC current | AC breaker | Max. PV input | Peak backup (10 s) |
|---|---|---|---|---|---|
| 3.8 kW | 3,840 W | 16 A | 20 A | 7,680 W | 8,640 W |
| 4.8 kW | 4,800 W | 20 A | 25 A | 9,600 W | 8,640 W |
| 5.7 kW | 5,760 W | 24 A | 30 A | 11,520 W | 8,640 W |
| 7.6 kW | 7,680 W | 32 A | 40 A | 15,360 W | 17,100 W |
| 9.6 kW | 9,600 W | 40 A | 50 A | 19,200 W | 17,100 W |
| 11.5 kW | 11,500 W | 48 A | 60 A | 23,000 W | 17,100 W |
💡 What it means for you
SIGENERGY energy controller: 23 kW of PV on four MPPT
Oversizing is where the SIGENERGY energy controller pulls ahead. First, each of the four MPPT inputs accepts 16 A and one string. Then, the MPPT window runs from 50 to 550 V, with a 600 V maximum and a 100 V start-up. Consequently, strings of 10 to 13 modern 400 to 450 W modules fit on each tracker. With four trackers, that is 23 kW of DC on an 11.5 kW inverter, a 2:1 ratio. The surplus is not wasted. It charges the battery or feeds the EV charger, and clipping only happens once everything is full.
⚡ The Perma Batteries tip
Backup output and 0 ms switchover with the Sigen LoadHub
In backup mode, the controller delivers its full nominal power at 240 V and half of it per 120 V leg. Then, it surges to 17.1 kW for 10 seconds on the 7.6, 9.6 and 11.5 kW settings. That is enough to start a central air conditioner or a well pump. Moreover, when paired with the Sigen LoadHub and Sigen Battery US, the load-side disruption time is 0 ms. The controller runs grid-forming at all times, and the LoadHub simply opens the grid side. However, Sigenergy specifies the 0 ms figure under one condition. The controller’s nominal power must exceed the total home load at the moment of the outage.
| Backup parameter | Value | Practical reading |
|---|---|---|
| Output at 240 V / 208 V | 3,840 to 11,500 W | equal to the configured rating |
| Output at 120 V, per leg | 1,920 to 5,750 W | balance the 120 V loads across both legs |
| Peak output, 10 s | 8,640 W (3.8 to 5.7 kW) · 17,100 W (7.6 to 11.5 kW) | motor starting margin |
| Switchover disruption | 0 ms | with LoadHub + Sigen Battery US only |
| Voltage THD | < 2 % | clean sine wave for electronics |
| Frequency | 59.3 to 60.5 Hz | IEEE 1547-2018 ride-through |
⚠️ 208 V is not three-phase
SigenStor BAT 6.0 and 9.0 US: up to six modules per controller
The SigenStor EC SP sits on top of the battery stack and connects to it through the backplane, with no external DC cabling. First, it accepts SigenStor BAT 6.0 US and BAT 9.0 US modules, at 300 to 600 V. Then, up to six modules stack under one controller, for roughly 36 to 54 kWh. Moreover, the high-voltage battery bus keeps current low, so cables stay small and losses stay under control. Finally, several controllers can be paralleled for larger homes, each with its own stack.
| Supported modules | SigenStor BAT 6.0 US · SigenStor BAT 9.0 US |
| Battery voltage range | 300 to 600 V DC |
| Modules per controller | up to 6 |
| Typical stack energy | about 6 to 54 kWh per controller |
| Connection | stacked, backplane connectors · no external DC cables |
| Black start | multi-source: PV, battery or generator through the LoadHub |
✅ Advantage: one tower, one permit package
SIGENERGY energy controller EMS, AFCI and rapid shutdown
The energy management system runs inside the controller, not in the cloud. First, it arbitrates between self-consumption, time-of-use, backup reserve and EV charging. Then, it coordinates the LoadHub smart loads and the generator port. Moreover, the mySigen app exposes the whole energy flow, with per-load Sankey diagrams. On the safety side, the SIGENERGY energy controller integrates AFCI per UL 1699B and supports NEC 690.12 rapid shutdown. It is also listed to UL 1741 SB for the latest grid-support functions. Finally, UL 3141 covers the power control system functions that let you avoid a service upgrade.
| Function | Standard | Why it matters |
|---|---|---|
| Arc-fault detection (AFCI) | UL 1699B | required by NEC 690.11 on DC circuits |
| Rapid shutdown | NEC 690.12 | transmitter integrated, pairs with roof-top RSD devices |
| Grid support, ride-through | UL 1741 SB · IEEE 1547-2018 | accepted by all US utilities under the 2018 standard |
| Power control system | UL 1741 CRD · UL 3141 | limits export or import to stay within the panel rating |
| EMI | FCC Part 15 Class B | residential-grade emissions |
Installing the SigenStor EC SP: NEMA 4X, 77 lb, smart air cooling
The SigenStor EC SP measures 27.6 in wide, 11.8 in high and 10.2 in deep, and weighs 77.1 lb. First, it stacks on top of the battery modules or mounts alone on the wall bracket when used without storage. Then, the NEMA 4X enclosure handles outdoor installation. The operating range runs from -22 to 140 °F. Moreover, smart air cooling keeps the fan quiet at partial load and only ramps up at full power. Finally, communication runs over Wi-Fi, Fast Ethernet or RS485. The optional Sigen CommMod US adds 4G where there is no internet.
| Dimensions (W × H × D) | 27.6 × 11.8 × 10.2 in · 700 × 300 × 260 mm |
| Weight | 77.1 lb · 35 kg |
| Enclosure | NEMA 4X |
| Cooling | smart air cooling |
| Operating temperature | -22 to 140 °F · -30 to 60 °C |
| Storage temperature | -40 to 158 °F · -40 to 70 °C |
| Max. altitude | 13,123 ft · 4,000 m |
| Communication | WLAN · Fast Ethernet · RS485 · Sigen CommMod US (4G / 3G) |
Which SigenStor EC SP configuration do you need?
| Scenario | Rating | PV array | Battery | Add-ons |
|---|---|---|---|---|
| Self-consumption, 100 A service | 5.7 kW | up to 11.5 kW | 2 × BAT 6.0 | none |
| Partial backup, 200 A service | 7.6 kW | up to 15.4 kW | 2 to 3 × BAT 9.0 | LoadHub for smart loads |
| Whole-home backup | 11.5 kW | up to 23 kW | 4 to 6 × BAT 9.0 | LoadHub + generator |
| Large home, EV | 2 × 11.5 kW in parallel | up to 46 kW | 2 stacks | LoadHub + Sigen EV DC |
Start from the service size and the backup goal. Then, set the rating to stay within the panel’s busbar rule. Fill the PV input to 2:1 if the roof allows. Because the SKU is unique, a wrong first guess costs a software change, not a new inverter.
SIGENERGY energy controller datasheet
| Product | Sigen Energy Controller Split Phase US · SigenStor EC SP US · part no. 11040057 |
| Configurable ratings | 3.8 / 4.8 / 5.7 / 7.6 / 9.6 / 11.5 kW |
| Max. PV power | 7,680 / 9,600 / 11,520 / 15,360 / 19,200 / 23,000 W |
| Max. DC input voltage | 600 V |
| Nominal DC input voltage | 360 V |
| Start-up voltage | 100 V |
| MPPT voltage range | 50 to 550 V |
| MPP trackers / strings per tracker | 4 / 1 |
| Max. input current per MPPT | 16 A |
| Max. short-circuit current per MPPT | 20 A |
| Nominal AC power (on-grid) | 3,840 / 4,800 / 5,760 / 7,680 / 9,600 / 11,500 W |
| Max. continuous AC current | 16 / 20 / 24 / 32 / 40 / 48 A |
| AC switch current rating | 20 / 25 / 30 / 40 / 50 / 60 A |
| Nominal output voltage | 240 / 120 V split phase · 208 / 120 V |
| Grid frequency range | 59.3 to 60.5 Hz |
| Power factor | 0.8 leading to 0.8 lagging |
| Current THD | < 2 % |
| Max. efficiency | 97.8 % |
| CEC efficiency | 97.61 % |
| Backup output at 240 / 208 V | 3,840 to 11,500 W |
| Backup output at 120 V | 1,920 to 5,750 W |
| Peak output power (10 s) | 8,640 W (3.8 to 5.7 kW) · 17,100 W (7.6 to 11.5 kW) |
| Voltage THD (backup) | < 2 % |
| Backup switch disruption time | 0 ms (with Sigen LoadHub and Sigen Battery US) |
| Supported battery modules | SigenStor BAT 6.0 US · BAT 9.0 US |
| Battery voltage range | 300 to 600 V |
| Dimensions (W × H × D) | 27.6 × 11.8 × 10.2 in · 700 × 300 × 260 mm |
| Weight | 77.1 lb · 35 kg |
| Operating temperature | -22 to 140 °F · -30 to 60 °C |
| Storage temperature | -40 to 158 °F · -40 to 70 °C |
| Relative humidity | 0 to 95 % |
| Max. operating altitude | 13,123 ft · 4,000 m |
| Cooling | smart air cooling |
| Enclosure | NEMA 4X |
| Communication | WLAN · Fast Ethernet (FE) · RS485 · Sigen CommMod US (4G / 3G) |
| Standards | UL 1741 · UL 1741 SB · UL 1741 CRD · IEEE 1547-2018 · IEEE 1547.1-2020 · UL 1998 · UL 991 · UL 1699B · UL 3141 · CP 65 · FCC Part 15 Class B |
| Warranty | 10 years |
| Datasheet version | 20260717 |
FAQ — SIGENERGY energy controller
What is the SIGENERGY energy controller?
How much PV can the SigenStor EC SP accept?
Does it keep working during a power outage?
Which batteries are compatible?
Can it run without a battery?
Is the rapid shutdown transmitter integrated?
What is the difference between the six power ratings?
What warranty does Sigenergy offer?
Powered By EmbedPress
Powered By EmbedPress
| Version | 48-48-5120, 48-48-5120-H (heated) |
|---|
Related products
-
SIGENERGY Sigen EVDC
$2,850.00 -
SIGENERGY LoadHub
$1,599.00




Reviews
There are no reviews yet.