• +1 (415) 818-0845
  • inquiries-usa@perma-batteries.com
Facebook Youtube Linkedin
  • Sigenergy
  • Edison battery
  • Guides
Products — SIGENERGY
SIGENERGY EC ControllerField programmable · 11 kW max · 120/240 VAC split phase Sigen Loading HubSplit phase · load management & backup transfer SigenStor BAT 9.0Stackable battery modules · 9 kWh each Sigen EV DC ChargerBidirectional DC charging · V2H ready View all All-in-one systems
Resources
Operation manualsUser & installer manuals, firmware notes Certificates & listingsUL, NEC compliance, spec sheets How to installStep-by-step guides, commissioning, app setup Schematics & wiringSingle-line diagrams, grid-tied & off-grid

Browse all resources

Not sure what size you need?

Size your off-grid SIGENERGY system in 2 minutes based on your loads, location and sun hours.

Off-grid solar simulator
Victron + Edison bundles
Edison 12V kit— Victron Edison 24V kit— Victron Edison 48V kit— Victron
Sol-Ark + Edison bundles
Edison 48V kit— Sol-Ark
Bare batteries
Edison batteries— cells & packs, no inverter
Documentation
Datasheet & specifications Installation manual Maintenance & electrolyte Charge settings (Victron / Sol-Ark) Warranty & certifications

Which Edison battery for your project? Our simulator guides you based on your loads, your site and your budget.

Solar simulator
Solar batteries
Battery chemistries compared— LFP, NiFe, LTO How to size an off-grid battery bank Lifespan & cycle life BMS & pack safety Off-grid solar 101
Wiki & documentation
SIGENERGY— EC Controller, SigenStor Edison batteries Sol-Ark Victron
Inverters
Off-grid vs hybrid inverter MPPT, how it works AC vs DC coupling Split phase 120/240 V explained Generator backup & auto-start
Codes & regulations
Where can I install my batteries? NEC for stand-alone systems— Art. 690, 706, 710 UL 9540 / 9540A, what it means Permits & inspections (AHJ) 30% federal tax credit (ITC)— off-grid eligible Canada: CSA & CEC basics

Not sure where to start? Our technical guides break down every choice, spec sheet in hand.

All guides Solar simulator
$0.00 0 Cart
Need a quote ?
12V EDISON OFF GRID SOLAR KIT
48V Victron off-grid pre-wired (120V)
December 8, 2025
sigenstor BAT 9 US
SIGENERGY Sigenstor BAT
October 21, 2026
SIGENERGY EC SP

SIGENERGY Sigenstor EC SP

$2,499.00

Split-phase hybrid inverter + EMS

SIGENERGY Energy Controller · SigenStor EC SP US
120 / 240 V · one SKU configurable 3.8 to 11.5 kW · up to 23 kW PV · stacks on SigenStor BAT 6.0 / 9.0
⚡11.5 kW nominal · 48 A
one SKU, 6 field-set ratings
☀️23 kW PV input · 4 MPPT × 16 A
2:1 DC/AC ratio, 50 to 550 V
🔋Up to 6 battery modules
SigenStor BAT 6.0 / 9.0 US · 300 to 600 V
🏠Backup 11.5 kW at 240 V
peak 17.1 kW for 10 s
⏱️0 ms switchover
with Sigen LoadHub
📈Efficiency 97.8 % max
97.61 % CEC · THD < 2 %
🛡️AFCI · NEC 690.12 RSD
UL 1741 SB · UL 3141
🌡️NEMA 4X · -22 to 140 °F
smart air cooling · 77 lb
✅10-year warranty
Wi-Fi · Ethernet · RS485 · 4G option
Need a system design? →
Category: Sigenergy
Share
0
  • Description
  • Additional information
  • Reviews 0

SIGENERGY energy controller SigenStor EC SP US: the 11.5 kW split-phase hybrid with 23 kW of PV input

Hybrid inverter + EMS · 120 / 240 V split phase · one SKU, field-configurable from 3.8 to 11.5 kW · 4 MPPT · 2:1 DC/AC ratio · NEMA 4X · 10-year warranty

11.5 kW nominal23 kW PV input4 MPPT · 16 A17.1 kW peak (10 s)0 ms backup switchUp to 6 battery modulesNEMA 4X outdoor10-year warranty
sigenergy sigenstor EC SP
⚙️One SKU, six power ratings.
The SigenStor EC SP US ships as a single part number (11040057) and is set in the field to 3.8, 4.8, 5.7, 7.6, 9.6 or 11.5 kW. You buy one controller and match it to your service, your permit and your PV array.
Datasheet
Installation manual

The SIGENERGY energy controller at a glance

ProductSigen Energy Controller Split Phase US · SigenStor EC SP US · part no. 11040057
Rolehybrid inverter and energy management system of the SigenStor 5-in-1 stack
AC output120 / 240 V split phase · 208 / 120 V supported · 60 Hz
Nominal power3.8 / 4.8 / 5.7 / 7.6 / 9.6 / 11.5 kW · field-configurable
PV inputup to 23 kW · 4 MPPT · 16 A each · 50 to 550 V MPPT window · 600 V max.
Backup output11.5 kW at 240 V · 5.75 kW at 120 V · 17.1 kW peak for 10 s
Backup switchover0 ms load-side disruption with Sigen LoadHub and Sigen Battery US
BatterySigenStor BAT 6.0 / 9.0 US · 300 to 600 V · up to 6 modules per controller
Efficiency97.8 % max. · 97.61 % CEC
EnclosureNEMA 4X · smart air cooling · -22 to 140 °F
Dimensions and weight27.6 × 11.8 × 10.2 in (700 × 300 × 260 mm) · 77.1 lb (35 kg)
CertificationsUL 1741 · UL 1741 SB · UL 1741 CRD · IEEE 1547-2018 · UL 1699B · UL 3141 · FCC Part 15 Class B

The SIGENERGY energy controller, sold as the SigenStor EC SP US, is the brain of the SigenStor home energy system. First, it is a split-phase hybrid inverter with four MPPT inputs and up to 23 kW of PV. Then, it embeds the energy management system that decides where power goes: loads, battery, grid or EV. Moreover, it stacks directly on SigenStor BAT 6.0 and 9.0 US battery modules, up to six per controller. Finally, it ships as a single SKU that the installer configures from 3.8 to 11.5 kW. In short, it replaces the inverter, the EMS and the battery gateway with one outdoor-rated unit.

“The number that sold me on the EC SP is the 2:1 DC/AC ratio. On an 11.5 kW controller you can hang 23 kW of panels, which means the battery fills in winter when a conventional hybrid is still starved. Add the 0 ms switch with the LoadHub and the fact that one SKU covers every service size, and the stocking problem disappears for the installer.”
— Julien, Perma Batteries

One SKU, six power ratings: configuring the SigenStor EC SP

Sigenergy ships a single hardware unit and unlocks the output power in software. First, the installer selects 3.8, 4.8, 5.7, 7.6, 9.6 or 11.5 kW during commissioning. Then, the controller limits its on-grid and backup output accordingly. As a result, the same box fits a 100 A townhouse service and a 200 A service with a 23 kW array. Moreover, the AC switch rating scales with the setting, from 20 A to 60 A, so the breaker size follows the configuration. However, the PV input limit also scales: 2:1 of the configured AC rating, from 7.68 kW to 23 kW.

Configured ratingNominal AC powerMax. AC currentAC breakerMax. PV inputPeak backup (10 s)
3.8 kW3,840 W16 A20 A7,680 W8,640 W
4.8 kW4,800 W20 A25 A9,600 W8,640 W
5.7 kW5,760 W24 A30 A11,520 W8,640 W
7.6 kW7,680 W32 A40 A15,360 W17,100 W
9.6 kW9,600 W40 A50 A19,200 W17,100 W
11.5 kW11,500 W48 A60 A23,000 W17,100 W

💡 What it means for you

Pick the rating from the permit, not the price list. A 7.6 kW setting keeps you under the 120 % rule on a 200 A panel with a 40 A breaker, and you can still raise it to 11.5 kW later if a panel upgrade or a LoadHub changes the picture.

SIGENERGY energy controller: 23 kW of PV on four MPPT

Oversizing is where the SIGENERGY energy controller pulls ahead. First, each of the four MPPT inputs accepts 16 A and one string. Then, the MPPT window runs from 50 to 550 V, with a 600 V maximum and a 100 V start-up. Consequently, strings of 10 to 13 modern 400 to 450 W modules fit on each tracker. With four trackers, that is 23 kW of DC on an 11.5 kW inverter, a 2:1 ratio. The surplus is not wasted. It charges the battery or feeds the EV charger, and clipping only happens once everything is full.

⚡ The Perma Batteries tip

Four independent trackers mean four orientations. Put east and west strings on separate MPPT, and keep the shaded string alone. With 16 A per input, pair modules with an Isc under 16 A at STC and under 20 A short-circuit, which rules out most 600 W-class G12 panels but fits every 54- or 72-cell residential module.
SIGENERGY SIGENSTOR EC SP

Backup output and 0 ms switchover with the Sigen LoadHub

In backup mode, the controller delivers its full nominal power at 240 V and half of it per 120 V leg. Then, it surges to 17.1 kW for 10 seconds on the 7.6, 9.6 and 11.5 kW settings. That is enough to start a central air conditioner or a well pump. Moreover, when paired with the Sigen LoadHub and Sigen Battery US, the load-side disruption time is 0 ms. The controller runs grid-forming at all times, and the LoadHub simply opens the grid side. However, Sigenergy specifies the 0 ms figure under one condition. The controller’s nominal power must exceed the total home load at the moment of the outage.

sigenstor ec sp
Backup parameterValuePractical reading
Output at 240 V / 208 V3,840 to 11,500 Wequal to the configured rating
Output at 120 V, per leg1,920 to 5,750 Wbalance the 120 V loads across both legs
Peak output, 10 s8,640 W (3.8 to 5.7 kW) · 17,100 W (7.6 to 11.5 kW)motor starting margin
Switchover disruption0 mswith LoadHub + Sigen Battery US only
Voltage THD< 2 %clean sine wave for electronics
Frequency59.3 to 60.5 HzIEEE 1547-2018 ride-through

⚠️ 208 V is not three-phase

The EC SP accepts 208 / 120 V from two legs plus neutral of a 120 / 208 V wye service. That covers many condos and light-commercial units, but the controller remains a split-phase inverter: it does not produce three-phase output.

SigenStor BAT 6.0 and 9.0 US: up to six modules per controller

The SigenStor EC SP sits on top of the battery stack and connects to it through the backplane, with no external DC cabling. First, it accepts SigenStor BAT 6.0 US and BAT 9.0 US modules, at 300 to 600 V. Then, up to six modules stack under one controller, for roughly 36 to 54 kWh. Moreover, the high-voltage battery bus keeps current low, so cables stay small and losses stay under control. Finally, several controllers can be paralleled for larger homes, each with its own stack.

Supported modulesSigenStor BAT 6.0 US · SigenStor BAT 9.0 US
Battery voltage range300 to 600 V DC
Modules per controllerup to 6
Typical stack energyabout 6 to 54 kWh per controller
Connectionstacked, backplane connectors · no external DC cables
Black startmulti-source: PV, battery or generator through the LoadHub

✅ Advantage: one tower, one permit package

Controller, battery and optional EV DC module share one NEMA 4X enclosure line and one UL 9540 system listing. For the AHJ, the whole SigenStor tower is a single certified energy storage system.
SIGENERGY SIGENSTOR EC SP

SIGENERGY energy controller EMS, AFCI and rapid shutdown

The energy management system runs inside the controller, not in the cloud. First, it arbitrates between self-consumption, time-of-use, backup reserve and EV charging. Then, it coordinates the LoadHub smart loads and the generator port. Moreover, the mySigen app exposes the whole energy flow, with per-load Sankey diagrams. On the safety side, the SIGENERGY energy controller integrates AFCI per UL 1699B and supports NEC 690.12 rapid shutdown. It is also listed to UL 1741 SB for the latest grid-support functions. Finally, UL 3141 covers the power control system functions that let you avoid a service upgrade.

FunctionStandardWhy it matters
Arc-fault detection (AFCI)UL 1699Brequired by NEC 690.11 on DC circuits
Rapid shutdownNEC 690.12transmitter integrated, pairs with roof-top RSD devices
Grid support, ride-throughUL 1741 SB · IEEE 1547-2018accepted by all US utilities under the 2018 standard
Power control systemUL 1741 CRD · UL 3141limits export or import to stay within the panel rating
EMIFCC Part 15 Class Bresidential-grade emissions

Installing the SigenStor EC SP: NEMA 4X, 77 lb, smart air cooling

The SigenStor EC SP measures 27.6 in wide, 11.8 in high and 10.2 in deep, and weighs 77.1 lb. First, it stacks on top of the battery modules or mounts alone on the wall bracket when used without storage. Then, the NEMA 4X enclosure handles outdoor installation. The operating range runs from -22 to 140 °F. Moreover, smart air cooling keeps the fan quiet at partial load and only ramps up at full power. Finally, communication runs over Wi-Fi, Fast Ethernet or RS485. The optional Sigen CommMod US adds 4G where there is no internet.

Dimensions (W × H × D)27.6 × 11.8 × 10.2 in · 700 × 300 × 260 mm
Weight77.1 lb · 35 kg
EnclosureNEMA 4X
Coolingsmart air cooling
Operating temperature-22 to 140 °F · -30 to 60 °C
Storage temperature-40 to 158 °F · -40 to 70 °C
Max. altitude13,123 ft · 4,000 m
CommunicationWLAN · Fast Ethernet · RS485 · Sigen CommMod US (4G / 3G)

Which SigenStor EC SP configuration do you need?

ScenarioRatingPV arrayBatteryAdd-ons
Self-consumption, 100 A service5.7 kWup to 11.5 kW2 × BAT 6.0none
Partial backup, 200 A service7.6 kWup to 15.4 kW2 to 3 × BAT 9.0LoadHub for smart loads
Whole-home backup11.5 kWup to 23 kW4 to 6 × BAT 9.0LoadHub + generator
Large home, EV2 × 11.5 kW in parallelup to 46 kW2 stacksLoadHub + Sigen EV DC

Start from the service size and the backup goal. Then, set the rating to stay within the panel’s busbar rule. Fill the PV input to 2:1 if the roof allows. Because the SKU is unique, a wrong first guess costs a software change, not a new inverter.

SIGENERGY energy controller datasheet

ProductSigen Energy Controller Split Phase US · SigenStor EC SP US · part no. 11040057
Configurable ratings3.8 / 4.8 / 5.7 / 7.6 / 9.6 / 11.5 kW
Max. PV power7,680 / 9,600 / 11,520 / 15,360 / 19,200 / 23,000 W
Max. DC input voltage600 V
Nominal DC input voltage360 V
Start-up voltage100 V
MPPT voltage range50 to 550 V
MPP trackers / strings per tracker4 / 1
Max. input current per MPPT16 A
Max. short-circuit current per MPPT20 A
Nominal AC power (on-grid)3,840 / 4,800 / 5,760 / 7,680 / 9,600 / 11,500 W
Max. continuous AC current16 / 20 / 24 / 32 / 40 / 48 A
AC switch current rating20 / 25 / 30 / 40 / 50 / 60 A
Nominal output voltage240 / 120 V split phase · 208 / 120 V
Grid frequency range59.3 to 60.5 Hz
Power factor0.8 leading to 0.8 lagging
Current THD< 2 %
Max. efficiency97.8 %
CEC efficiency97.61 %
Backup output at 240 / 208 V3,840 to 11,500 W
Backup output at 120 V1,920 to 5,750 W
Peak output power (10 s)8,640 W (3.8 to 5.7 kW) · 17,100 W (7.6 to 11.5 kW)
Voltage THD (backup)< 2 %
Backup switch disruption time0 ms (with Sigen LoadHub and Sigen Battery US)
Supported battery modulesSigenStor BAT 6.0 US · BAT 9.0 US
Battery voltage range300 to 600 V
Dimensions (W × H × D)27.6 × 11.8 × 10.2 in · 700 × 300 × 260 mm
Weight77.1 lb · 35 kg
Operating temperature-22 to 140 °F · -30 to 60 °C
Storage temperature-40 to 158 °F · -40 to 70 °C
Relative humidity0 to 95 %
Max. operating altitude13,123 ft · 4,000 m
Coolingsmart air cooling
EnclosureNEMA 4X
CommunicationWLAN · Fast Ethernet (FE) · RS485 · Sigen CommMod US (4G / 3G)
StandardsUL 1741 · UL 1741 SB · UL 1741 CRD · IEEE 1547-2018 · IEEE 1547.1-2020 · UL 1998 · UL 991 · UL 1699B · UL 3141 · CP 65 · FCC Part 15 Class B
Warranty10 years
Datasheet version20260717

FAQ — SIGENERGY energy controller

What is the SIGENERGY energy controller?
It is the hybrid inverter and energy management unit of the SigenStor system, sold as the SigenStor EC SP US. It converts PV and battery power to 120 / 240 V split phase, manages on-grid and backup operation, and controls the whole home energy flow from one unit.
How much PV can the SigenStor EC SP accept?
Up to 23 kW at the 11.5 kW setting, on four MPPT inputs of 16 A each, with a 50 to 550 V MPPT window. The limit is always twice the configured AC rating.
Does it keep working during a power outage?
Yes. It delivers its full nominal power in backup, up to 11.5 kW at 240 V with a 17.1 kW peak for 10 seconds. With the Sigen LoadHub and Sigen Battery US, the switchover disruption is 0 ms.
Which batteries are compatible?
SigenStor BAT 6.0 US and BAT 9.0 US modules, from 300 to 600 V, up to six modules stacked under one controller. Third-party batteries are not supported.
Can it run without a battery?
Yes. The controller works as a grid-tied PV inverter without storage, and battery modules can be added later by stacking them underneath.
Is the rapid shutdown transmitter integrated?
Yes. The controller supports NEC 690.12 rapid shutdown and pairs with roof-top RSD devices. AFCI per UL 1699B is also built in.
What is the difference between the six power ratings?
Nothing in the hardware. One SKU (part no. 11040057) is set in the field to 3.8, 4.8, 5.7, 7.6, 9.6 or 11.5 kW, which scales the AC output, the breaker size and the PV input limit.
What warranty does Sigenergy offer?
10 years on the controller. Refer to the Sigenergy limited warranty document for the exact terms in the United States.

Powered By EmbedPress

Powered By EmbedPress

Version

48-48-5120, 48-48-5120-H (heated)

Reviews

There are no reviews yet.

Be the first to review “SIGENERGY Sigenstor EC SP” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • sigenstor EVDC

    SIGENERGY Sigen EVDC

    $2,850.00
  • sigenstor BAT 9 US

    SIGENERGY Sigenstor BAT

    $2,280.00 – $2,850.00Price range: $2,280.00 through $2,850.00
  • SIGENERGY LOADHUB

    SIGENERGY LoadHub

    $1,599.00