SIGENERGY Sigenstor EC SP
October 21, 2026
SIGENERGY Sigen EVDC
October 21, 2026SIGENERGY Sigenstor BAT
$2,280.00 – $2,850.00Price range: $2,280.00 through $2,850.00
Stackable LiFePO₄ battery module
BAT 6.0 US · BAT 9.0 US
4.5 / 6.9 kW peak for 10 s
54.24 kWh per controller
DC-DC optimizer in every module
self-guiding connectors, no cables
UL 1973 · UL 9540 · UL 9540A
natural convection, silent
live battery status per module
137 lb (6.0) · 172 lb (9.0)
SigenStor BAT 6.0 and 9.0 US: the stackable SIGENERGY battery, 5.84 to 52.6 kWh usable
LiFePO₄ modules · 6.02 or 9.04 kWh · 3.0 / 4.6 kW continuous · built-in DC-DC optimizer · mix 6.0 and 9.0 freely · up to 6 modules per controller · Type 4X
Choose BAT 6.0 US (part no. 11130020) or BAT 9.0 US (part no. 11130019). Both fit the same SigenStor stack, and the built-in DC-DC optimizer lets you mix sizes and ages. Ships by freight truck only.
The SigenStor BAT at a glance
| Models | SigenStor BAT 6.0 US (11130020) · SigenStor BAT 9.0 US (11130019) |
| Chemistry | lithium iron phosphate (LiFePO₄) |
| Total / usable energy | 6.02 / 5.84 kWh · 9.04 / 8.76 kWh |
| Continuous charge / discharge | 3,000 W (6.0) · 4,600 W (9.0) |
| Peak power (10 s) | 4,500 W (6.0) · 6,900 W (9.0) |
| Stack | 1 to 6 modules per SigenStor EC SP US · up to 54.24 kWh total, 52.6 kWh usable |
| Optimizer | built-in DC-DC per module · mix 6.0 and 9.0, new and old |
| Enclosure | Type 4X · natural convection · floor-standing or wall-mounted |
| Dimensions | 30.2 × 10.6 × 10.4 in (767 × 270 × 265 mm), both models |
| Weight | 136.7 lb (62 kg) · 172.0 lb (78 kg) |
| Operating temperature | -4 to 131 °F (-20 to 55 °C) |
| Certifications | UL 1973 · UL 1998 · UL 9540 · UL 9540A · UN 38.3 · FCC Part 15 Class B |
The SigenStor BAT is the battery module of the SigenStor home energy system, the SIGENERGY battery that stacks under the EC SP controller. First, it comes in two sizes: 6.02 kWh and 9.04 kWh, with 5.84 and 8.76 kWh usable. Then, each module carries its own DC-DC optimizer. A 6.0 and a 9.0, or an old module and a new one, share the same stack without derating. Moreover, up to six modules stack under one controller, for 54.24 kWh. Finally, the Type 4X enclosure and natural convection make the stack fit for outdoor installation. There is no fan to fail.
“The optimizer per module is the feature people underestimate. On most systems, adding a battery three years later means the old pack drags the new one down. With the SigenStor BAT, each module runs its own DC-DC stage, so a customer can start with two 6.0 modules and add a 9.0 when the EV arrives. That is the only residential battery I know of where expansion is truly plug-and-play.”
— Julien, Perma Batteries
SigenStor BAT 6.0 vs 9.0: same footprint, two capacities
Both modules share the same 30.2 × 10.6 × 10.4 in enclosure, so the stack looks identical whatever the mix. First, the BAT 6.0 US stores 6.02 kWh, with 5.84 kWh usable and 3.0 kW of continuous power. Then, the BAT 9.0 US stores 9.04 kWh, with 8.76 kWh usable and 4.6 kW. Moreover, both surge to 1.5 times their continuous rating for 10 seconds. The price per kWh favors the 9.0, but the 6.0 keeps the entry ticket lower and the lifting weight under 140 lb. Consequently, most installs start with 9.0 modules and keep the 6.0 for the odd extra kilowatt-hour.
| Parameter | SigenStor BAT 6.0 US | SigenStor BAT 9.0 US |
|---|---|---|
| Part number | 11130020 | 11130019 |
| Total energy | 6.02 kWh | 9.04 kWh |
| Usable energy | 5.84 kWh | 8.76 kWh |
| Max. charge / discharge power | 3,000 W | 4,600 W |
| Peak power, 10 s | 4,500 W | 6,900 W |
| Weight | 136.7 lb (62 kg) | 172.0 lb (78 kg) |
| Dimensions (W × H × D) | 30.2 × 10.6 × 10.4 in | 30.2 × 10.6 × 10.4 in |
💡 What it means for you
Stack up to six SigenStor BAT modules: 54 kWh per controller
The stack is the heart of the SigenStor design. First, modules plug into each other through self-guiding connectors, with no DC cables or busbars to make up. Then, the EC SP US controller sits on top and sees the whole stack on its 300 to 600 V battery bus. Moreover, you can add a module at any time: the new one plugs into the existing tower and the optimizers balance the mix. Finally, six modules of 9.04 kWh total 54.24 kWh, enough for two days of autonomy in a typical off-grid home.
| Modules | Energy (all 9.0) | Usable | Battery power | Typical use |
|---|---|---|---|---|
| 1 × BAT 9.0 | 9.04 kWh | 8.76 kWh | 4.6 kW | self-consumption, time-of-use |
| 2 × BAT 9.0 | 18.08 kWh | 17.52 kWh | 9.2 kW | partial-home backup |
| 3 × BAT 9.0 | 27.12 kWh | 26.28 kWh | 13.8 kW | whole-home backup, full EC SP power |
| 4 × BAT 9.0 | 36.16 kWh | 35.04 kWh | 18.4 kW | backup + EV charging |
| 6 × BAT 9.0 | 54.24 kWh | 52.56 kWh | 27.6 kW | off-grid, two days of autonomy |
⚡ The Perma Batteries tip
Built-in DC-DC optimizer: mix new and old, 6.0 and 9.0
Every SigenStor BAT module embeds a DC-DC converter between its cells and the stack bus. First, that converter sets each module’s current independently, so a 6.0 and a 9.0 deliver their own share of power. Then, it keeps an older module from limiting the newer ones. Moreover, it isolates a faulty module without taking the stack down. As a result, Sigenergy allows mixing capacities and generations in one tower. Most competitors forbid it. Finally, the optimizer runs the AI-assisted cycle management that Sigenergy claims extends cycle life.
✅ Advantage: expansion without penalty
Safety: LiFePO₄, UL 9540 and multi-layer protection
Lithium iron phosphate is the stable end of the lithium family, with no oxygen release in thermal runaway. On top of the chemistry, Sigenergy layers protection at cell, module and system level. First, the module is listed to UL 1973 and the complete SigenStor system to UL 9540. UL 9540A covers fire propagation testing. Then, UL 1998 covers the software in the BMS. Moreover, UN 38.3 certifies transport. Finally, the Type 4X enclosure keeps water, dust and corrosion out. That is why the stack can live outside without a shelter.
| Standard | Scope | Why it matters |
|---|---|---|
| UL 1973 | battery module | required for any stationary lithium battery in the US |
| UL 9540 | complete energy storage system | what the AHJ asks for under NEC 706 and the fire code |
| UL 9540A | thermal runaway propagation test | allows reduced spacing and indoor installation per fire code |
| UL 1998 | software in programmable components | BMS firmware safety |
| UN 38.3 | transport | freight shipping of lithium batteries |
| FCC Part 15 Class B | EMI | residential-grade emissions |
Powered By EmbedPress
Installation: floor-standing or wall-mounted, Type 4X, no fan
The SigenStor BAT installs as a floor-standing tower or wall-mounted, indoors or out. First, each module measures 30.2 in wide, 10.6 in high and 10.4 in deep. A six-module tower with the controller stands about 75 in tall. Then, the 172 lb weight of a BAT 9.0 calls for a two-person lift or a lifting aid. Moreover, natural convection cooling means silent operation and no filter to clean. Finally, the operating range runs from -4 to 131 °F, and storage from -13 to 140 °F.
| Dimensions per module (W × H × D) | 30.2 × 10.6 × 10.4 in · 767 × 270 × 265 mm |
| Weight | 136.7 lb (6.0) · 172.0 lb (9.0) |
| Installation | floor-standing or wall-mounted |
| Enclosure | Type 4X |
| Cooling | natural convection, silent |
| Operating temperature | -4 to 131 °F · -20 to 55 °C |
| Storage temperature | -13 to 140 °F · -25 to 60 °C |
| Relative humidity | 5 to 95 % |
| Max. altitude | 13,123 ft · 4,000 m |
| Shipping | freight truck only |
⚠️ Cold-weather note
Which SigenStor BAT configuration do you need?
| Scenario | Modules | Usable energy | Controller setting | Add-ons |
|---|---|---|---|---|
| Time-of-use arbitrage | 1 × BAT 9.0 | 8.76 kWh | 5.7 to 7.6 kW | none |
| Partial-home backup | 2 × BAT 9.0 | 17.5 kWh | 7.6 to 9.6 kW | LoadHub |
| Whole-home backup | 3 × BAT 9.0 | 26.3 kWh | 11.5 kW | LoadHub + generator |
| Backup + EV | 4 × BAT 9.0 | 35.0 kWh | 11.5 kW | LoadHub + Sigen EV DC |
| Off-grid home | 6 × BAT 9.0 | 52.6 kWh | 11.5 kW | LoadHub + generator |
Count the kilowatt-hours you want to carry overnight, then add one day of margin for an off-grid site. Because the modules mix freely, you can start with a BAT 6.0 and add 9.0 units later.
SigenStor BAT datasheet
| Models | SigenStor BAT 6.0 US (11130020) · SigenStor BAT 9.0 US (11130019) |
| Battery type | LiFePO₄ |
| Total energy capacity | 6.02 kWh · 9.04 kWh |
| Usable energy capacity | 5.84 kWh · 8.76 kWh (100 % DoD, 0.2C, 77 °F, beginning of life) |
| Max. charge / discharge power | 3,000 W · 4,600 W |
| Peak charge / discharge power (10 s) | 4,500 W · 6,900 W |
| Modules per controller | up to 6 · max. 54.24 kWh |
| Optimizer | built-in DC-DC per module · mixed capacities supported |
| Weight | 136.7 lb (62 kg) · 172.0 lb (78 kg) |
| Dimensions (W × H × D) | 30.2 × 10.6 × 10.4 in · 767 × 270 × 265 mm |
| Storage temperature | -13 to 140 °F · -25 to 60 °C |
| Operating temperature | -4 to 131 °F · -20 to 55 °C |
| Relative humidity | 5 to 95 % |
| Max. operating altitude | 13,123 ft · 4,000 m |
| Cooling | natural convection |
| System enclosure type | Type 4X |
| Installation | floor-standing · wall-mounted |
| Compatible controller | SigenStor EC SP US · 300 to 600 V battery bus |
| Standards | UL 1973 · UL 1998 · UL 9540 · UL 9540A · UN 38.3 · CP 65 · FCC Part 15 Class B |
| Shipping | freight truck only |
FAQ — SigenStor BAT
What is the SigenStor BAT?
What is the difference between SigenStor BAT 6.0 and 9.0?
Can I mix 6.0 and 9.0 modules in one stack?
How many SigenStor BAT modules fit under one controller?
Can I expand the battery later?
Is the SigenStor BAT rated for outdoor installation?
Does the SIGENERGY battery provide backup during an outage?
Which certifications does it carry?
Powered By EmbedPress
Powered By EmbedPress
| Version | 6.0, 9.0 |
|---|
Related products
-
SIGENERGY Sigen EVDC
$2,850.00 -
SIGENERGY Sigenstor EC SP
$2,499.00 -
SIGENERGY LoadHub
$1,599.00




Reviews
There are no reviews yet.