SIGENERGY Sigenstor BAT
October 21, 2026
Discover AES Rackmount 48-5120
October 21, 2026SIGENERGY Sigen EVDC
$2,850.00
Bidirectional DC EV charger module
about 100 miles of range per hour
car powers the home or the grid
400 V and 800 V platforms
cable 16.4 ft or 24.6 ft
on the SigenStor DC bus
same footprint as a battery module
short-circuit, polarity, thermal
smart air cooling · ≤ 89 lb
requires Sigen Energy Controller US
Sigen EV DC V2X: the 25 kW bidirectional DC charger built into the SigenStor tower
SigenStor EVDC 25 kW US · 25 kW charge and 25 kW discharge · 150 to 1,000 V · CCS1 or NACS · V2H and V2G · 100 % solar charging · NEMA 4X
The Sigen EV DC module only works stacked with the Sigen Energy Controller US. Bidirectional V2H / V2G also depends on the vehicle: the EV must support DC discharge over CCS1 or NACS.
The Sigen EV DC V2X at a glance
| Product | Sigen EV DC Charging Module 25 kW US · SigenStor EVDC |
| Role | bidirectional DC fast charger module of the SigenStor 5-in-1 system |
| Charging power | 25 kW DC, up to 80 A |
| Discharging power | 25 kW DC · vehicle-to-home (V2H) and vehicle-to-grid (V2G) |
| Output voltage | 150 to 1,000 V · 400 V and 800 V vehicle platforms |
| Connector | CCS1 or NACS · integrated cable 16.4 ft (5 m) or 24.6 ft (7.5 m) |
| Requires | Sigen Energy Controller US (SigenStor EC SP US) |
| Control | mySigen app · RFID card · no-auth mode · OTA updates · remote diagnostics |
| Enclosure | NEMA 4X · smart air cooling · -22 to 122 °F |
| Dimensions and weight | 27.56 × 10.63 × 10.24 in (700 × 270 × 260 mm) · ≤ 89 lb (≤ 40 kg) |
| Protection | short-circuit · over / under voltage · overload · over temperature · reverse polarity · welded contactor check |
The Sigen EV DC V2X module turns the SigenStor tower into a 25 kW DC fast charger. First, it charges any CCS1 or NACS vehicle between 150 and 1,000 V, so both 400 V and 800 V platforms are covered. Then, it runs the other way: the same 25 kW flow back from the car to the home or the grid. Moreover, it draws directly from the DC bus shared with the PV array and the SigenStor battery. That allows true 100 % solar charging with no AC conversion. Finally, it stacks on the tower like a battery module, in the same NEMA 4X enclosure. In short, the car becomes the biggest battery in the house.
“A 25 kW DC charger at home used to mean a three-phase service and a separate cabinet. Here it is one module in the stack, fed by the same bus as the panels. The part that matters is the discharge: a 75 kWh EV parked in the garage is three SigenStor towers' worth of backup. Once your car supports V2H, that is a different conversation about how much stationary battery you really need.”
— Julien, Perma Batteries
25 kW DC charging: five times faster than a Level 2 charger
A typical Level 2 charger delivers 7 to 11 kW in AC. The car’s on-board charger then converts it to DC. The Sigen EV DC skips that step. First, it delivers up to 25 kW of DC directly to the pack, at up to 80 A. Then, the output spans 150 to 1,000 V. That covers everything from a compact 400 V hatchback to an 800 V truck. Consequently, a 75 kWh battery gains about 100 miles of range per hour of charging. However, the 25 kW come from the DC bus. PV, SigenStor battery and grid import add up. With 23 kW of PV at noon, the car charges on sunshine alone.
| Charger | Power | Path | Approx. range per hour |
|---|---|---|---|
| Level 1, 120 V outlet | 1.4 kW | AC, on-board charger | 4 to 5 miles |
| Level 2, 48 A | 11.5 kW | AC, on-board charger | 35 to 45 miles |
| Sigen EV DC | 25 kW | DC, direct to pack | about 100 miles |
💡 What it means for you
V2H and V2G: 25 kW from the car to the home or the grid
Bidirectional charging is the headline feature of the Sigen EV DC V2X. First, in vehicle-to-home mode, the module discharges the EV at up to 25 kW into the DC bus. The Energy Controller then converts it to 120 / 240 V for the house. Then, in vehicle-to-grid mode, the same power exports to the utility where a program exists. Moreover, the EMS treats the car as one more storage asset. It holds a minimum state of charge for the morning drive and uses the rest for backup or arbitrage. However, Sigenergy notes that V2X may be limited by the vehicle. The EV must support DC discharge over its CCS1 or NACS port. Few models do so today.
| Mode | Direction | Use case | Requires |
|---|---|---|---|
| Charging | grid / PV / battery → EV | daily charging, 100 % solar charging | any CCS1 or NACS vehicle |
| V2H | EV → home | backup during outages, evening self-consumption | V2X-capable EV |
| V2G | EV → grid | utility programs, export at peak price | V2X-capable EV + utility program |
| Smart load management | EMS-controlled | charge on PV surplus, pause at low battery SOC | mySigen app |
⚠️ Check the car before you count on V2H
100 % green charging on the SigenStor DC bus
Most home chargers sit on the AC side of the inverter. Solar power is converted to AC, then back to DC in the car. The Sigen EV DC sits on the DC side. First, PV strings feed the Energy Controller’s MPPT inputs. Then, the controller routes DC straight to the EV module and the battery. As a result, one conversion stage disappears. The EMS can then promise 100 % solar charging by throttling the car to the PV surplus. Finally, the mySigen app shows where every kilowatt-hour in the car came from.
✅ Advantage: one tower, one permit, one app
Protection: contactor check, reverse polarity and thermal limits
A 25 kW DC port needs the protections of a public fast charger. The module includes them. First, short-circuit, overload and over / under voltage protection cover the output. Then, reverse polarity protection guards the connector. Moreover, a welded contactor check verifies that the DC contactors opened before the cable is released. Finally, over-temperature protection and smart air cooling keep the power stage inside its limits in a 122 °F garage.
| Protection | Status | Why it matters |
|---|---|---|
| Short-circuit | supported | cable or connector fault |
| Over / under voltage | supported | mismatch with the vehicle pack |
| Overload | supported | current above 80 A |
| Over temperature | supported | hot garage, long sessions |
| Reverse polarity | supported | wiring error at installation |
| Welded contactor check | supported | ensures the port is dead before unplugging |
Installation: stacked module, NEMA 4X, 5 m or 7.5 m cable
The EV DC module has the same footprint as a SigenStor battery module: 27.56 in wide, 10.63 in high and 10.24 in deep. First, it stacks into the tower and connects through the backplane, with no DC cabling. Then, it weighs under 89 lb, so two people handle it. Moreover, the integrated cable comes in 16.4 ft (5 m) or 24.6 ft (7.5 m). Those are the maximum lengths allowed without a cable management system in Canada and the US. Finally, the NEMA 4X enclosure and the -22 to 122 °F operating range allow outdoor installation next to the driveway.
| Dimensions (W × H × D) | 27.56 × 10.63 × 10.24 in · 700 × 270 × 260 mm |
| Weight | ≤ 89 lb · ≤ 40 kg (net, without connector and wall-mount parts) |
| Cable length | 16.4 ft (5 m) or 24.6 ft (7.5 m), integrated |
| Connector | CCS1 or NACS, specified at order |
| Enclosure | NEMA 4X |
| Cooling | smart air cooling |
| Operating temperature | -22 to 122 °F · -30 to 50 °C |
| Storage temperature | -40 to 158 °F · -40 to 70 °C |
| Max. altitude | 13,123 ft · 4,000 m |
| Authentication | RFID card · mySigen app · no authentication |
| Remote | OTA updates · remote diagnostics |
⚡ The Perma Batteries tip
Which SigenStor setup do you need for the Sigen EV DC?
| Goal | Controller | Battery | PV | Note |
|---|---|---|---|---|
| Solar-only daytime charging | EC SP 11.5 kW | 1 × BAT 9.0 | 15 to 23 kW | car throttled to PV surplus |
| Fast charging at any hour | EC SP 11.5 kW | 3 × BAT 9.0 | 15 to 23 kW | battery tops up the grid import to reach 25 kW |
| V2H backup home | EC SP 11.5 kW + LoadHub | 2 × BAT 9.0 | any | car covers multi-day outages |
| Two EVs | 2 × EC SP in parallel | 2 stacks | up to 46 kW | one EV DC module per tower |
The grid alone rarely delivers 25 kW on a residential service. In practice, the module reaches full power when PV, battery and grid import add up. That is why it belongs in a complete SigenStor system rather than next to a bare controller.
Sigen EV DC V2X datasheet
| Product | Sigen EV DC Charging Module 25 kW US · SigenStor EVDC |
| Max. charging power | 25 kW |
| Max. discharging power | 25 kW |
| Output voltage range | 150 to 1,000 V |
| Max. output current | 80 A |
| Charging connector | CCS1 / NACS |
| Short-circuit protection | supported |
| Over / under voltage protection | supported |
| Overload protection | supported |
| Over temperature protection | supported |
| Reverse polarity protection | supported |
| Welded contactor check | supported |
| Dimensions (W × H × D) | 27.56 × 10.63 × 10.24 in · 700 × 270 × 260 mm |
| Weight | ≤ 89 lb · ≤ 40 kg (net) |
| Storage temperature | -40 to 158 °F · -40 to 70 °C |
| Operating temperature | -22 to 122 °F · -30 to 50 °C |
| Relative humidity | 5 to 95 % |
| Max. operating altitude | 13,123 ft · 4,000 m |
| Cooling | smart air cooling |
| System enclosure type | NEMA 4X |
| Integrated charging cable length | 16.4 ft (5 m) or 24.6 ft (7.5 m) |
| Authentication | RFID card · app · no authentication |
| Application | bidirectional charging (V2H, V2G) · smart load management |
| User interfaces | LED indicator · app · RFID |
| Remote functions | OTA · remote diagnostics |
| Requires | Sigen Energy Controller US |
| Datasheet version | 20260605 |
FAQ — Sigen EV DC V2X
What is the Sigen EV DC V2X?
Does the Sigen EV DC work on its own?
Which vehicles can it charge?
Which vehicles support V2H and V2G?
Can it really charge on 100 % solar?
How fast is 25 kW?
Is it rated for outdoor installation?
How is charging authorized?
Powered By EmbedPress
Powered By EmbedPress
| Version | 6.0, 9.0 |
|---|
Related products
-
SIGENERGY LoadHub
$1,599.00 -
SIGENERGY Sigenstor EC SP
$2,499.00




Reviews